Project Description
KEYENCE LV-12SA in stock
Model | LV-12SA | |||
Type | Expansion unit (1 line) | |||
Main unit/expansion unit | ||||
Applicable model | LV-S61/S41/S41L/S31/S71/S72 | |||
Control output | NPN open-collector × 2 channels, 40 VDC maximum, 100 mA or less per output | |||
Response time | ExceptLV-S31 | ULTRA | 4 ms | |
SUPER | 2 ms | |||
TURBO | 500 µs | |||
FINE | 250 µs | |||
HSP | 80 µs | |||
LV-S31standard mode | 500 µs | |||
LV-S31standard mode | SPED2 | 2 ms | ||
SPED3 | 8 ms | |||
SPED4 | 32 ms | |||
LV-S31High-speed mode | 250 µs | |||
Control input | Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input | |||
Number of interference prevention units | ULTRA | 4 | ||
SUPER | ||||
TURBO | 2 | |||
FINE | ||||
HSP | 0 | |||
Unit expansion | Up to 16 expansion units can be connected (a total of 17 units).*1 | |||
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*2 | ||
Power consumption | Normal | 1.5 W or less (62.5 mA or less at 24 V) | ||
Ratings | Eco-Half Eco-All | 1.35 W or less (57.3 mA or less at 24 V) | ||
Environmental resistance | Ambient temperature | -10 to +55 °C 14 to 131 °F (No freezing)*3 | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06″, 2 hours in each of the X, Y, and Z axis | |||
Material | Main unit | Main body, cover: Polycarbonate | ||
Weight | Approx. 80 g (including 2 m 6.6′ cable) | |||
*1 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less. 1 or 2 Units: -10 to 55°C 14 to 131°F, 3 to 10 Units: -10 to 50°C 14 to 122°F, 11 to 16 Units: -10 to 45°C 14 to 113°F *2 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % or less *3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C 14 to 131°F, 3 to 10 units connected: -10 to +50 °C 14 to 122°F, 11 to 16 units connected: -10 to +45 °C 14 to 113°F |