ASCON tecnologic temprature controller K32ERRRR K32EORRR K32CORRR K32COORR TLK32ERRRR TLK32EORRR TLK32CORRR TLK32COORR in stock
- Panel mount controller 78 x 35 mm
- Available with “Sensitive Touch” keyboard
- 1 Configurable probe input
- 2 digital inputs
- Up to 4 digital outputs
– PID controller with:
* Independent timer
* 8 segment programmer (optional)
* Wattmeter
* Counter for worked days and hours
* Compressor protection timer - TTL or RS485 Modbus-RTU ports
- 2 display lines, 4 digit, h 7 mm, red and green colour
Process inputs:
1 temperature probe input
– Thermocouples: J, K, R, S,T
– PTC KTY81-121 (990 Ω @ 25 °C)
– NTC 103AT-2 (10KΩ @ 25 °C)
– RTD: Pt100
– Voltage (V): 0..1 V, 0/1…5 V , 0/2…10 V
– Voltage (mV): 0…50 mV, 0…60 mV, 12 …60 mV
– Current (mA): 0/4…20 mA
– Custom linearisation and IR probes (J,K type)
Overall accuracy: ± (0,5 % span ± 1 digit @25 °C); Tc S: ± (1 % span ± 1 digit @ 25 °C)
2 digital inputs
– Free Voltage
Keyboard
4 multifunction keys
– Mechanical:
– “Sensitive Touch”
Process outputs
Up to 5 outputs
OUT1
– RELAY SPDT, 8A
– SSR Drive
OUT2
– RELAY SPDT, 8A
– SSR Drive
OUT3/OUT4
– RELAY SPST-NO, 5A
– SSR Drive
Power supply:
– 12 VAC/VDC
– 24 VAC/VDC
– 100… 240 VAC (50/60 Hz)
Transmitter power supply: 10 VDC (±10%), 20 mA max.
Functions
– ON/OFF control with neutral zone
– PID single action or double action (Heat/Cool) with overshoot control
– Bumpless ramp to set point change
– Start-up delay
– Independent timer with 5 functioning modes (optional)
– Setpoint change from digital inputs
– Digital Setpoint retransmission (Note 1)
– Up to 4 memorized setpoints
– 8 segment programmer with events recovery, 2 events and guaranteed soak (optional)
– Wattmeter for calculating the instantaneous power and energy used
– Counter for days and hours worked
with programmable threshold for programmed maintenance
– Compressor protection timer
Autotuning
– Adaptive Autotuning
– Oscillatory
– Fast
Alarms
– Up to 4 configurable alarms + loop break alarm
Communication and programming:
Interfaces
Communication on TTL port to:
– Universal programming key
– Remote display
– RS 485 serial interface
RS 485 port with ModBus RTU protocol (optional)
Programming/configuration tools:
– Configurable parameter level “Promotion”
– Configuration software available for PC
Installation
Mounting method: panel mount
Case dimensions: 78 x 35 mm, depth 75.5 mm
Connections
Communication port connection
5 Pole TTL Port
Connection
24 poles 2.5 mm² screw terminals block
Front protection: IP65 front frame protection, with gasket and screw brakets
Display and indicators
2 display lines, 4 digit, h 7 mm, red and green colour
Connectable to:
– Programming key A01 for PC connection, backup and other functions
– SCADA for monitoring, traceability and remote management
– DX and DY gateways for remote monitoring
Notes
1) Digital Setpoint retransmission available only with RS485 port option or external adapter from TTL