AP-C33 2018-10-22T15:21:44+08:00

Project Description

KEYENCE    AP-C33  in  stock

NPN

Model AP-C30K AP-C31K AP-C33K
Type Multi range, NPN Negative pressure, NPN Positive pressure, NPN
Rated pressure Negative pressure mode: 0 to -29.9 inchHg
Positive pressure mode: 0 to 29.5 inchHg
Compound pressure mode: 29.9 to -29.9 inchHg
0 to -29.9 inchHg 0 to 145.0 Psi
Fluid type Air or non-corrosive gases
Type of pressure Gauge pressure
Display 3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43″ (11 mm)) Display cycle: 10 times/s
Operation indicator Red LED x 2 (corresponding to control output 1 and 2)
Display resolution Multi range: Negative/Positive 0.1 inchHg, Compound 0.1 inchHg Normal mode: 0.1 inchHg, Focus mode: 0.01 inchHg Normal mode: 0.2 Psi, Focus mode: 0.02 Psi
Power consumption Normal 12 V: 720 mW (60 mA) or less, 24 V: 960 mW (40 mA) or less
Display temperature characteristic ±1 % of F.S. max.
Hysteresis Variable (Standard: 0.5 % of F.S.)*1
Response time (Chattering prevention function) 2.5, 5, 100, or 500 ms (selectable)
I/O Analog output 1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)
Zero-shift input Input time: 2 ms or more. (or analog output selectable)
Control output NPN open collector 100 mA max. (at 40 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)
Pressure port NPT 1/8 180 ° rotation
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
Power consumption Eco mode 12 V: 480 mW (40 mA) or less, 24 V: 720 mW (30 mA) or less
Environmental resistance Pressure resistance 500 kPa 1.5 MPa
Ambient temperature 0 to 50 °C 32 to 122 °F (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm 0.06″, 2 hours in each of the X, Y, and Z directions
Material Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting
Accessories Power supply cord (6.6′ 2-m with connector) Power supply cord (6.6′ 2-m with connector), Unit seal
Weight Approx. 30 g (without cable) /Approx. 85 g (with 6.6′ 2-m cable)
*1 A standard of 0.2 % of FS applies while in focus mode.

PNP

Model AP-C30KP AP-C31KP AP-C33KP
Type Multi range, PNP Negative pressure, PNP Positive pressure, PNP
Rated pressure Negative pressure mode: 0 to -29.9 inchHg
Positive pressure mode: 0 to 29.5 inchHg
Compound pressure mode: 29.9 to -29.9 inchHg
0 to -29.9 inchHg 0 to 145.0 Psi
Fluid type Air or non-corrosive gases
Type of pressure Gauge pressure
Display 3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43″ (11 mm)) Display cycle: 10 times/s
Operation indicator Red LED x 2 (corresponding to control output 1 and 2)
Display resolution Multi range: Negative/Positive 0.1 inchHg, Compound 0.1 inchHg Normal mode: 0.1 inchHg, Focus mode: 0.01 inchHg Normal mode: 0.2 Psi, Focus mode: 0.02 Psi
Power consumption Normal 12 V: 900 mW (75 mA) or less, 24 V: 1,320 mW (55 mA) or less
Display temperature characteristic ±1 % of F.S. max.
Hysteresis Variable (Standard: 0.5 % of F.S.)*1
Response time (Chattering prevention function) 2.5, 5, 100, or 500 ms (selectable)
I/O Analog output 1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)
Zero-shift input Input time: 2 ms or more. (or analog output selectable)
Control output PNP open collector 100 mA max. (at 30 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)
Pressure port NPT 1/8 180 ° rotation
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
Power consumption Eco mode 12 V: 600 mW (50 mA) or less, 24 V: 960 mW (40 mA) or less
Environmental resistance Pressure resistance 500 kPa 1.5 MPa
Ambient temperature 0 to 50 °C 32 to 122 °F (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm 0.06″, 2 hours in each of the X, Y, and Z directions
Material Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting
Accessories Power supply cord (6.6′ 2-m with connector) Power supply cord (6.6′ 2-m with connector), Unit seal
Weight Approx. 30 g (without cable) /Approx. 85 g (with 6.6′ 2-m cable)
*1 A standard of 0.2 % of FS applies while in focus mode.

If  you  want to buy it,sent an inquiry to us

GET A QUOTE